Database Contributor Review

SCAI-SCI Gait Dataset: Motion Capture of Overground Walking in Adults with Spinal Cord Injury

ORCID iD for Diego Paez Granados,  ,  ,  ,  , 

Published Nov. 25, 2026 · Version 1.0.0
When using this resource, please cite:

Paez Granados, D., Natraj, S., Amrein, S., Kupper, L., Ruepp, M. V., & Eriks-Hoogland, I. (2026). SCAI-SCI Gait Dataset: Motion Capture of Overground Walking in Adults with Spinal Cord Injury (version 1.0.0). PhysioNet. RRID:SCR_007345. https://doi.org/10.13026/rjsm-p475

Additionally, please cite the original publication:

Natraj S, M. Ruepp, Y. Li, Riener R, Eriks-Hoogland I, Paez-Granados D. Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury. https://arxiv.org/abs/2610.05552

Please include the standard citation for PhysioNet:

Pollard, T., Moody, B. E., Lehman, L., Gow, B., Fernandes, C., Xie, C., Johnson, A., Mark, R. G., & Heldt, T. (2026). PhysioNet as a global platform for biomedical research. Nature Health. https://doi.org/10.1038/s44360-026-00096-z. Available from: https://pmc.ncbi.nlm.nih.gov/articles/PMC13641116/

Abstract

Instrumented gait analysis is the reference for assessing walking after spinal cord injury (SCI), but it needs a motion-capture laboratory that few clinics have, and markerless video methods are rarely validated on neurological gait. This dataset pairs both for 240 adults with traumatic or non-traumatic SCI assessed in the gait laboratory of the Swiss Paraplegic Centre, Nottwil. It contains 300 motion-capture trials (C3D: 20 lower-body markers, two force plates, and surface EMG in 194 trials), 300 three-dimensional SMPL body-model sequences reconstructed with CameraHMR from sagittal video of the same sessions, 299 renderings of those sequences, and a clinical table of the 240 participants coded to the International SCI Core Data Set v3.0 (sex, age group, neurologic category, completeness, etiology, time since injury), with grouped lower-extremity motor score, SCIM III mobility, spasticity, vibration sense and walking condition. An index describes every file, per-trial spatiotemporal gait parameters are provided, and one data dictionary documents every column. The data were de-identified following the SPHN risk assessment framework; no image of a participant is released. The resource supports benchmarking of markerless 3D pose and shape estimation on pathological gait, biomechanical modelling, and the study of gait patterns after SCI.


Background

Many people with SCI regain some ability to walk: roughly 30-40 % can ambulate without external support [@vanhedel2008]. Walking capacity is central to independence in daily life [@ditunno2008], and ambulatory people with SCI show altered gait patterns, such as ankle or hip-flexor weakness, spasticity and compensatory strategies [@ditunno2009, @krawetz1996, @murphy2019].

Clinically, gait after SCI is usually measured with timed tests such as the 10-metre walk test or the timed up-and-go [@awai2016]. Three-dimensional gait analysis (3DGA) adds the kinematics and kinetics of each body segment and can guide treatment decisions [@murphy2019], but reference data for SCI are scarce: studies are small and intra-subject variability is high [@awai2014, @awai2016]. 3DGA also requires an optoelectronic laboratory with force plates, which limits it to specialised centres.

Markerless methods that recover 3D human pose and shape from a single video could bring gait assessment to any clinic or to the home. They are, however, trained and evaluated almost exclusively on able-bodied movement. Atypical postures, asymmetric steps, walking aids and compensation are exactly where they may fail, and until now no public dataset has paired clinical 3DGA with video-based body reconstructions in a neurological population.

This dataset was assembled to close that gap. An earlier study of this cohort benchmarked monocular 3D pose estimation against laboratory motion capture for the assessment of gait kinematics in SCI [@natraj2026]. The SMPL sequences released here were reconstructed with CameraHMR [@patel2025], the human mesh recovery method that reconstructed the most valid frames, with close to the lowest joint error, in a comparison of five methods on this cohort (manuscript in preparation). The dataset is released so that others can evaluate markerless methods on pathological gait, and study gait patterns in a large, clinically characterised SCI cohort.


Methods

Participants

Adults (18 years or older at the examination) with traumatic or non-traumatic SCI who could walk independently for at least 10 m, with or without aids, and were assessed in the gait laboratory of the Swiss Paraplegic Centre (SPC), Nottwil, between 1 January 2010 and 31 December 2022. Excluded were people without a diagnosis of SCI, with another neurological disorder or a gait impairment not related to SCI, and assessments with an assistive devices.

Assessment protocol

The recordings come from routine clinical three-dimensional gait analyses (3DGA), the assessments that the study protocol uses retrospectively; nothing was recorded for research. Each assessment was a 10-metre walk test (10MWT) [@awai2014, @awai2016] performed in the motion-capture laboratory.

  • Preparation: retro-reflective markers were attached to anatomical landmarks of the pelvis and lower limbs following the Istituti Ortopedici Rizzoli (IOR) lower-body protocol [@leardini2007]. In the assessments with EMG, surface electrodes were placed over the muscles to be recorded.
  • Task: the participant walked along the 10 m walkway of the laboratory at a self-selected, comfortable speed, crossing the two force plates embedded in the floor, barefoot or in their own shoes and with their usual walking aids (the walking condition is in the clinical table).
  • Repetitions: walks were repeated until 6 to 8 gait cycles had been captured. Each released C3D file is one walk along the walkway.
  • Video: a sagittal video of each session was recorded with the motion capture.

The clinical examination recorded in the medical record (ISNCSCI, SCIM III, Modified Ashworth scale, manual muscle testing and joint range of motion) was part of the same routine care. These data were transferred from the medical record into a secuTrial electronic data capture system by a research assistant, under a coded study identifier.

Equipment

  • Motion capture: Qualisys Miqus optoelectronic cameras with Qualisys Track Manager (QTM) software (Qualisys AB, Sweden). Nominal marker rate 200 Hz; the released trials were recorded at 200 Hz (163 trials), 100 Hz (129 trials), 246 Hz (8 trials). The release keeps the 20 lower-body markers of the IOR protocol (L_IAS, L_IPS, R_IPS, R_IAS, L_FTC, L_FLE, L_FAX, L_TTC, L_FAL, L_FCC, L_FM1, L_FM5, R_FTC, R_FLE, R_FAX, R_TTC, R_FAL, R_FCC, R_FM1, R_FM5), in mm in the laboratory frame.
  • Force plates: two Bertec 4060-06 strain-gauge force plates (Bertec Corporation, USA), 40 x 60 cm each, six channels per plate (three forces, three moments), embedded in the walkway and sampled with the camera system as analog channels. Nominal rate 1000 Hz; analog rates in the released trials: 1500 Hz (108 trials), 1000 Hz (85 trials), 2000 Hz (77 trials), 500 Hz (21 trials), 1722 Hz (8 trials), 1600 Hz (1 trial).
  • Electromyography: Noraxon Ultium wireless surface EMG (Noraxon Inc., USA), nominal rate 2000 Hz, recorded into the same analog stream in 194 trials of 171 participants, most often from tibialis anterior and gastrocnemius lateralis, and in some trials from biceps femoris, vastus medialis, gluteus medius and rectus femoris.
  • Video: one sagittal camera, recorded by the motion-capture system and synchronised with it.

Data processing

Motion capture. In QTM, the camera data were reconstructed into 3D marker trajectories, the markers were labelled, gaps of up to 10 frames were filled by polynomial interpolation, and each walk was exported as a C3D file together with the force-plate and EMG analog channels. For the release, no trajectory or analog sample was filtered, resampled or otherwise changed. The header was reduced to the groups needed to read the data (see De-identification), every file was given the same 20 markers in one order, with a marker absent from a recording stored as missing (NaN), and files were renamed to the study number. Force-plate signals are the analog outputs of the plates in V, with the calibration matrix that converts them to forces and moments (C3D force-platform type 4); EMG is stored as exported.

SMPL body models. Each sagittal video was defaced and then processed frame by frame with CameraHMR [@patel2025], which estimates the camera and fits the SMPL body model [@loper2015]: root orientation and 23 joint rotations (axis-angle), 10 shape coefficients, and from these the 24 joint positions and the 6,890-vertex mesh. The per-frame fits were assembled in frame order into one sequence per video at 15 frames per second, expressed relative to the root (translation set to zero) with Y up, and stored as NumPy archives (.npz) that hold numeric arrays only. Each sequence was also rendered as a video of the grey mesh on a black background. The source videos are not released. The walking direction of each sequence was taken from the file name or, where the name does not give it, inferred from the root orientation.

Gait parameters. Spatiotemporal parameters were computed for every trial from the released marker trajectories by one fixed procedure, without force plates and without filtering. Heel strikes and toe-offs were detected with the coordinate method of [@zenijajr2008]: a heel strike where the heel marker is furthest ahead of the pelvis along the direction of travel, a toe-off where the toe marker is furthest behind it. Only the part of the walk in which the pelvis moved faster than 0.15 m/s was used, and a stride counted only if it lasted 0.5 to 3 s and the foot and the pelvis advanced by the same distance within 30 %. From these strides the table gives walking speed, cadence, stride time and its coefficient of variation, stride and step length, step-length asymmetry, step width, and stance, swing and double-support percentages. A value that could not be measured is left empty and the column status gives the reason; 292 of 300 trials have at least one full gait cycle.

Curation and standardisation

Motion-capture trials, SMPL sequences and renders were matched to the clinical table by study identifier; every participant in the release has a clinical row and at least one recording. Byte-identical duplicate SMPL files were removed.

Standardisation. The clinical table is released in the International SCI Core Data Set v3.0 [@bieringsorensen2023]: sex, age group, neurologic category [@devivo2011], region of the neurological level, completeness (AIS A or B-E), traumatic or non-traumatic etiology and time since injury, each in the Core reporting groups. As Core v3.0 prescribes, motor and sensory levels are not reported separately, and the neurological level itself is given only as cohort counts. The lower-extremity motor score (ISNCSCI) and the SCIM III mobility total are released in 10-point bands, spasticity (Modified Ashworth) in three groups. The per-side levels, the individual muscle grades, joint range of motion and the SCIM items are not released.

De-identification

De-identification followed the SPHN Risk Assessment Template v2.1.2 and was carried out and verified with the SCAI Lab release toolkit.

  • Identifiers: participants are renumbered with study numbers that did not exist before; the key is kept only on the data server of the institution. No name, birth date, hospital number or calendar date is in any released file.
  • C3D headers: only the groups POINT, ANALOG, FORCE_PLATFORM and EVENT are kept, and free-text descriptions are blanked. Every other group, including the one in which the acquisition software stores patient fields, operator and timestamps, is removed. Trajectories and analog signals are unchanged.
  • Clinical table: the Core Data Set variables in their reporting groups (age in ISCoS groups, time since injury in Core groups, scores in bands); the neurological level, height, weight, subcategory, etiology codes and time in rehabilitation only as cohort counts; no per-side level, muscle grade or joint angle.
  • Video: no camera image is released. The SMPL model is a parametric template mesh without texture or facial geometry, fitted to defaced video; the renders show only that mesh on a black background.
  • Verification: every file header was audited field by field, the released files were searched for the identifiers of the source, a file-level re-identification red-team was run, and the SPHN risk assessment was scored from the released content.

Gait and body shape are biometric, and demographics are not k-anonymised; for this reason the dataset is distributed as credentialed-access data under a data use agreement that forbids re-identification.


Data Description

The release holds 240 participants. Every participant has a row in the clinical table and at least one motion-capture trial; 239 also have an SMPL sequence. 180 participants have one trial and 60 have two or more. All files are keyed by the pseudonymous studyID, which is part of every file name.

RELEASE_v1.5_SCAI-SCI-Gait/
├── MoCap_Data/      300 .c3d   mocap<studyID>-<trial>.c3d            218.5 MB
├── SMPL_Data/       300 .npy   v<studyID>_sagittal_<li|re>_defaced_smpl_sequence.npy   3.7 GB
├── SMPL_Videos/     299 .mp4   v<studyID>_sagittal_<li|re>_defaced.mp4   598.4 MB
├── metadata/        8 .csv   medical_metadata, data_dictionary, 6 cohort_counts_*
├── trials.csv       one row per released file
├── gait_parameters.csv   one row per MoCap trial
└── manifest.sha256  SHA-256 of every file (909 entries)

Motion capture (MoCap_Data/)

300 C3D files, one per trial (2.5-12.3 s). Each holds the 20 marker trajectories in mm (POINT), the analog channels (ANALOG: two force plates with 6 channels each and, in 194 trials, EMG), the force-plate geometry and calibration (FORCE_PLATFORM, type 4) and acquisition triggers (EVENT).

SMPL body models (SMPL_Data/, SMPL_Videos/)

300 .npy files, one per sagittal video, with per-frame arrays: frame_ids [F], global_orient [F,3], body_pose [F,69], betas [F,10], trans [F,3], joints [F,24,3] and vertices [F,6890,3]; 46-553 frames per sequence. 299 MP4 files render these sequences as a grey mesh on a black background; trials.csv links each render to its sequence (linked_file).

Tables

File Rows Content
metadata/medical_metadata.csv 240 the clinical table, 14 columns, one row per participant, in the International SCI Core Data Set v3.0 reporting groups
trials.csv 899 one row per file: modality, trial, frames, duration, rates, marker completeness, EMG muscles, force-plate channel map, analog units, SMPL frame range and walking direction
gait_parameters.csv 300 per trial: strides, walking speed, cadence, stride and step length, step width, stance, swing and double support, stride-time variability, and why a value is empty
metadata/cohort_counts_*.csv (6) - attributes released only as counts: etiology, height, loi, rehab, subcat, weight
metadata/data_dictionary.csv - every column of every table and every field of the C3D and SMPL files: label, type, units, coding and the standard it follows

Clinical table (metadata/medical_metadata.csv)

Column Content Coding
sex sex assigned at birth female; male
age_group_iscos age at examination 15-29; 30-44; 45-59; 60-74; 75+
neurologic_category neurologic category from the NLI and the AIS C1-4 AIS ABC; C5-8 AIS ABC; T1-S5 AIS ABC; AIS D any level; AIS E (no deficit)
neurological_level_region region of the neurological level of injury C1-4; C5-8; T1-S5; intact. The NLI itself is in cohort_counts_loi.csv only
ais_complete completeness of the injury complete (AIS A); incomplete (AIS B-E)
etiology_class etiology traumatic; non-traumatic. The Core etiology codes are in cohort_counts_etiology.csv
years_since_injury_group time from injury to the examination <1; 1-4; 5-9; 10-14; 15-19; 20-24; 25-29; 30+
lems_band lower-extremity motor score, 10-point band 0-9; 10-19; 20-29; 30-39; 40-50 (sum of the ten L2-S1 key muscles, 0-50); empty unless all ten are graded
scim_mobility_band SCIM III mobility: indoors, moderate distances, outdoors, stairs, wheelchair-car and ground-wheelchair transfers; total as recorded, 10-point band 0-9; 10-19; 20-30
walking_aid walking condition during the examination barefoot; shoes; with aid (crutches or a walking stick)
care_setting care setting at the examination inpatient; outpatient
vibration_sense deep (vibration) sensation, lower limbs normal; deviating
spasticity_mas lower-limb spasticity, Modified Ashworth Scale, grouped 0; 1-1+; 2-4

Cohort

Variable Participants (counts below 5 shown as <5)
Sex male: 179; female: 61
Age at examination (ISCoS groups) 45-59: 87; 30-44: 61; 60-74: 46; 15-29: 41; 75+: 5
Neurologic category AIS D any level: 213; T1-S5 AIS ABC: 18; AIS E (no deficit): 6; not recorded: <5; C1-4 AIS ABC: <5
Region of the neurological level T1-S5: 133; C5-8: 64; C1-4: 33; not recorded: 5; intact: 5
Completeness (AIS) incomplete: 229; complete: 9; not recorded: <5
Etiology traumatic: 171; non-traumatic: 67; not recorded: <5
Years since injury <1: 143; 1-4: 55; 5-9: 16; 25-29: 8; 15-19: 8; 10-14: 5; 30+: <5; 20-24: <5

Integrity: manifest.sha256 lists the SHA-256 of every file; check it with sha256sum -c manifest.sha256 in the release folder.


Usage Notes

The dataset supports (i) benchmarking of monocular 3D human pose and shape estimation on pathological gait against laboratory motion capture, as in [@natraj2026]; (ii) biomechanical analysis of gait after SCI with kinematics, ground reaction forces and EMG; and (iii) studies of how gait relates to lesion level, completeness, spasticity and muscle strength.

Reading the data

C3D files can be read with ezc3d [@michaud2021], the Biomechanical ToolKit [@barre2014] or any other C3D reader. The SMPL sequences are NumPy archives of numeric arrays and load with numpy.load, without enabling pickle. Viewers for both modalities, loading examples and the CameraHMR processing pipeline are in the code repository of the dataset [@scailab2026]. Rendering the mesh from the pose and shape parameters needs the SMPL model files, which are distributed under a separate licence [@maxplanckinstitute].

Join everything on studyID; trials.csv and gait_parameters.csv also carry the file path of each recording.

Conventions

  • SMPL (.npz): arrays frame_ids, global_orient, body_pose, betas, trans, joints and vertices; Y-up; trans is zero in every frame, so the sequences are root-relative; time comes from frame_ids at 15 frames per second; betas vary per frame.
  • MoCap: marker coordinates in mm; sampling rates vary between trials and were never resampled; missing marker samples are NaN; force-plate signals are in V with the calibration matrix in FORCE_PLATFORM and represent the force exerted on the plate.
  • The walking direction of each SMPL sequence is given in trials.csv (direction), from the file name or inferred from the root orientation (direction_source).

Known limitations

  • Which MoCap trial each SMPL sequence and render comes from is not recorded; they share the participant and session only.
  • No gait events are stored in the C3D files (the EVENT group holds only acquisition triggers); gait_parameters.csv detects strides from the marker trajectories.
  • EMG is stored as recorded in the C3D export. In 137 trials the analog channels carry generic names (Channel_NN); trials.csv gives the force-plate channel map and the named EMG muscles of every trial.
  • 37 trials have fewer than 90 % of frames with all markers present (trials.csv: markers_complete_pct).
  • 1 participant(s) have motion capture but no SMPL sequence.
  • The clinical table has empty cells where a value was not recorded.
  • The cohort is from one national rehabilitation centre and mostly incomplete injuries (AIS D); it may differ from other populations.

Access

Users must not attempt to identify any participant, link the data with other sources to that end, or share the data outside the terms of the data use agreement.


Release Notes

Version 1.0.0

First public release. Contents as described above. Compared with the internal assembly of September 2026: participants outside the approved protocol were excluded, the clinical table was completed for participants with recordings, a missing motion-capture trial was added, SMPL renders were included, and every file is described in trials.csv and the data dictionary.


Ethics

This is a retrospective further use of health-related data collected during clinical routine, under the Swiss Human Research Act (Art. 32-33) and the Human Research Ordinance. The project "Gait in ambulatory patients with spinal cord injury" was approved by the Ethikkommission Nordwest- und Zentralschweiz (EKNZ, BASEC 2022-00935), with Amendment 01 (study protocol v3.0) approved on 29 July 2026. Since 2010, every patient of the Swiss Paraplegic Centre is informed about the possible research use of their routine data and may refuse it; only data of patients who did not refuse were used. The data were de-identified before release (Methods) and are shared under a data use agreement that forbids re-identification.


Acknowledgements

We thank the patients of the Swiss Paraplegic Centre who supported the research, and the gait laboratory team who recorded and processed the assessments: Benjamin Hirsch, Kathrin Hartmann and Eleonora Bronckers.

This study was partially funded by the Schweizer Paraplegiker Stiftung and the ETH Zürich Foundation (2021-HS-348), within the Digital Transformation in Personalized Healthcare initiative for individuals with spinal cord injury.


Conflicts of Interest

No conflicts of interest to report.


References

  1. @vanhedel2008 van Hedel HJ, Wirz M, Dietz V. Standardized assessment of walking capacity after spinal cord injury: the European network approach. Neurol Res. 2008;30(1):61-73. https://doi.org/10.1179/016164107X230775
  2. @ditunno2008 Ditunno PL, Patrick M, Stineman M, Ditunno JF. Who wants to walk? Preferences for recovery after SCI: a longitudinal and cross-sectional study. Spinal Cord. 2008;46(7):500-506. https://doi.org/10.1038/sj.sc.3102172
  3. @ditunno2009 Ditunno J, Scivoletto G. Clinical relevance of gait research applied to clinical trials in spinal cord injury. Brain Res Bull. 2009;78(1):35-42. https://doi.org/10.1016/j.brainresbull.2008.09.003
  4. @krawetz1996 Krawetz P, Nance P. Gait analysis of spinal cord injured subjects: effects of injury level and spasticity. Arch Phys Med Rehabil. 1996;77(7):635-638. https://doi.org/10.1016/s0003-9993(96)90000-3
  5. @murphy2019 Murphy AT, Kravtsov S, Sangeux M, Rawicki B, New PW. Utilizing three dimensional clinical gait analysis to optimize mobility outcomes in incomplete spinal cord damage. Gait Posture. 2019;74:53-59. https://doi.org/10.1016/j.gaitpost.2019.08.001
  6. @awai2016 Awai L, Curt A. Locomotor recovery in spinal cord injury: insights beyond walking speed and distance. J Neurotrauma. 2016;33(15):1428-1435. https://doi.org/10.1089/neu.2015.4154
  7. @awai2014 Awai L, Curt A. Intralimb coordination as a sensitive indicator of motor-control impairment after spinal cord injury. Front Hum Neurosci. 2014;8:148. https://doi.org/10.3389/fnhum.2014.00148
  8. @natraj2026 Natraj S, Messmer T, Fujii Y, Suzuki K, Riener R, Eriks-Hoogland I, Paez-Granados D. 3D pose estimation for scalable remote gait kinematics assessment. npj Digit Med. 2026;9:37. https://doi.org/10.1038/s41746-025-02211-y
  9. @patel2025 Patel P, Black MJ. CameraHMR: Aligning people with perspective. In: International Conference on 3D Vision (3DV). 2025. arXiv:2411.08128 https://doi.org/10.48550/arXiv.2411.08128
  10. @leardini2007 Leardini A, Sawacha Z, Paolini G, Ingrosso S, Nativo R, Benedetti MG. A new anatomically based protocol for gait analysis in children. Gait Posture. 2007;26(4):560-571. https://doi.org/10.1016/j.gaitpost.2006.12.018
  11. @loper2015 Loper M, Mahmood N, Romero J, Pons-Moll G, Black MJ. SMPL: a skinned multi-person linear model. ACM Trans Graph. 2015;34(6):248. https://doi.org/10.1145/2816795.2818013
  12. @zenijajr2008 Zeni JA Jr, Richards JG, Higginson JS. Two simple methods for determining gait events during treadmill and overground walking using kinematic data. Gait Posture. 2008;27(4):710-714. https://doi.org/10.1016/j.gaitpost.2007.07.007
  13. @bieringsorensen2023 Biering-Sørensen F, Charlifue S, Chen Y, New PW, Noonan V, Post MWM, et al. International Spinal Cord Injury Core Data Set (version 3.0) - including standardization of reporting. Spinal Cord. 2023;61(1):65-68. https://doi.org/10.1038/s41393-022-00862-2
  14. @devivo2011 DeVivo MJ, Biering-Sørensen F, New P, Chen Y. Standardization of data analysis and reporting of results from the International Spinal Cord Injury Core Data Set. Spinal Cord. 2011;49(5):596-599. https://doi.org/10.1038/sc.2010.172
  15. @michaud2021 Michaud B, Begon M. ezc3d: an easy C3D file I/O cross-platform solution for C++, Python and MATLAB. J Open Source Softw. 2021;6(58):2911. https://doi.org/10.21105/joss.02911
  16. @barre2014 Barre A, Armand S. Biomechanical ToolKit: open-source framework to visualize and process biomechanical data. Comput Methods Programs Biomed. 2014;114(1):80-87. https://doi.org/10.1016/j.cmpb.2014.01.012
  17. @scailab2026 SCAI Lab. SCAI-SCI-Gait-Dataset: documentation, viewers and processing code [software]. GitHub; 2026. https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset
  18. @maxplanckinstitute Max Planck Institute for Intelligent Systems. SMPL: a skinned multi-person linear model, model files and licence. 2026. https://smpl.is.tue.mpg.de/