MGH/MF Waveform Database 1.0.0

File: <base>/mgh201.hea (1,138 bytes)
mgh201 8 360/0.476 1360800 11:40:38 11/10/1992
mgh201.dat 212 400(400)/mV 12 0 438 -28536 0 ECG lead I
mgh201.dat 212 400 12 0 47 -5919 0 ECG lead II
mgh201.dat 212 400 12 0 80 29701 0 ECG lead V
mgh201.dat 212 5.83(-1154)/mmHg 12 0 48 -24543 0 ART
mgh201.dat 212 17.76(-1398)/mmHg 12 0 -939 -23303 0 PAP
mgh201.dat 212 20 12 0 -962 5569 0 CVP
mgh201.dat 212 1000 12 0 90 18606 0 Resp. Imp.
mgh201.dat 212 1000 12 0 1114 -15027 0 CO2
#<age>: 70 <sex>: M <diagnoses>: Abdominal aortic aneurysm resection and grafting; Aortobifemoral bypass graft
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
#   Normal sinus rhythm @ 92 bpm
# RHYTHM DISTURBANCES:
#   Atrial ectopy
# ECG INTERPRETATION:
#   sn wave change
#   Prolonged QT interval
# HEMODYNAMIC DATA:
#   ART: 140/78
#   PAP: 44/22   	PCW: 15 (@ 5 min, 19 min, 27 min, 47 min)
#   RAP: 10
# WAVEFORM PATTERNS:
#   Pulsus paradox
#   Respiratory variation
# TECHNICAL COMMENTS:
#   PA and CVP on same transducer
#   PA turned off and CVP on @ 22 min
#   Zero @ 26 min
# RESPIRATORY DATA:
# RATE:   8/8 changed to 7/16 bpm
# MODE OF VENTILATION:
#   Controlled changed to IMV