Finger - PIP Database: Signals from Novel Biomedical FSR 1.0.0

File: <base>/Readme.txt (3,478 bytes)
Finger PIP: Force, Piezo, and PPG Finger Database (WFDB)
This database contains synchronised electrocardiogram (ECG), photoplethysmography (PPG), force-sensitive resistor (FSR), and piezoelectric (PZT) waveforms recorded from healthy adult volunteers to study pulse arrival time (PAT), pulse transit time (PTT), pulse wave velocity (PWV), and dicrotic notch (DN) detection at the finger.​
Data collection
Data was recorded in a single-centre clinical study at Western Sydney University under research ethics approval H15672. Twenty‑four participants’ biomedical data were recorded using three ECG electrodes (Einthoven triangle configuration: left arm, right arm, left leg) and with a distal PPG sensor and a custom “morphic DOT” sensor (combined FSR–PZT) applied to one or two fingers. For each participant, up to six 5‑minute recordings were obtained with different PZT hardware configurations and one‑finger or two‑finger placements: FSRHFP1, FSRHFP2 (high‑frequency PZT), FSRLFP1, FSRLFP2 (low‑frequency PZT), and LFPHFP1, LFPHFP2 (combined low‑ and high‑frequency PZT). All signals (ECG, PPG, FSR, PZT) from each session are recorded simultaneously at 10 kHz using a BIOPAC MP36 data acquisition system and are stored in WFDB format as 32 bit data.​
Signals and sensors
Each WFDB record contains four time‑aligned signals: a single‑lead ECG, an infrared PPG from a distal finger probe, an FSR channel (distal contact force sensing of the finger), and a PZT channel (high‑frequency, low‑frequency, or combined, depending on the set). The morphic DOT board provides analog conditioning and gain stages that give approximately 8.85× voltage gain for the recorded FSR channel and high‑ and low‑frequency bands for the PZT channels.
Annotations included
The database is accompanied by beat‑level annotations marking R‑peak locations in the ECG signal and peak (systolic), trough (foot), and dicrotic notch positions in each of the three arterial blood pressure surrogate waveforms (PPG, FSR, PZT). The algorithm used to locate the provided fiducial points is the subject of a research article yet to be published. Annotation types follow single‑character codes compatible with WRANN: ECG R‑peaks use code ‘ecg’; PPG, FSR and PZT peak, trough, and notch use ‘P’, ‘V’, and ‘N’respectively, following the ppg, fsr and pzt assignations. These fiducial labels enable direct computation and validation of PAT, PTT, PWV, and DN‑detection algorithms across all three modalities. From these annotations, per‑beat PAT from peaks (PATp), PAT from troughs/foots (PATf), and midpoint‑based PTT can be calculated.
File organization
Within the PhysioNet project, WFDB signal files (.dat) and header files (.hea) are organised by subject and recording condition, with record names encoding participant index and set (for example, TXX_FSRHFP1). For each record, corresponding annotation files (.ecg, .ppgP/.ppgV/.ppgN, .pztP/.pztV/.pztN, .fsrP/.fsrV/.fsrN) store the fiducial markers defined above. A separate technical report describes the hardware and pre-processing methods.
Usage, citation, and acknowledgements
These data are intended for research on pulse wave analysis, sensor fusion, non‑optical alternatives for PPG, fiducial point detection, and DN detection. Users should cite the associated technical report and any subsequent journal articles describing the finger PIP/morphic DOT dataset and algorithms.