mgh179 8 360 1200960 7:26:36 06/06/1991 mgh179.dat 212 250 12 0 -319 5899 0 ECG lead I mgh179.dat 212 250 12 0 -8 6788 0 ECG lead II mgh179.dat 212 250 12 0 -30 26177 0 ECG lead V mgh179.dat 212 12(-1214)/mmHg 12 0 -5 11637 0 ART mgh179.dat 212 17.58(-1099)/mmHg 12 0 -1043 19511 0 PAP mgh179.dat 212 20 12 0 -1038 683 0 CVP mgh179.dat 212 1000 12 0 -26 15966 0 Resp. Imp. mgh179.dat 212 1000 12 0 -994 -29545 0 CO2 #: 72 : F : Chronic obstructive lung disease with pneumonia # PHARMACOLOGIC SUPPORT: # Neosynephrine @ 59 mcg/min # GENERAL COMMENTS: # Power to monitor off @ 27 min - 28 min # Data collection ends @ 45 min # Final zero/cal pop test sequence @ 45 min - 50 min # Stop/FFW @ 52 min - 53 min # ECG recorded during chest physical therapy @ 53 min-end # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Normal sinus rhythm @ 87 bpm # ECG INTERPRETATION: # Nonspecific ST segment and T wave abnormalities # TECHNICAL COMMENTS: # Wandering baseline # Electrodes replaced @ 52 min # HEMODYNAMIC DATA: # ART: 110/60 (axillary) # PAP: 65/27 (39) PCW: 12 (@ 10 min, 18 min, 20 min, 52 min,= best) # RAP: 8 CO: 4.35 # WAVEFORM PATTERNS: # Pulmonary hypertension # Respiratory variation # TECHNICAL COMMENTS: # PA and CVP on same transducer # CVP @ 16 min - 19 min # RESPIRATORY DATA: # RATE: 12/20 bpm # MODE OF VENTILATION: # Intermittent mandatory ventilation