mgh122 8 360/0.476 583200 16:43:24 15/02/1993 mgh122.dat 212 250(400)/mV 12 0 449 -13002 0 ECG lead I mgh122.dat 212 250(400)/mV 12 0 445 10754 0 ECG lead II mgh122.dat 212 250(100)/mV 12 0 97 27416 0 ECG lead V mgh122.dat 212 12(-1340)/mmHg 12 0 35 30940 0 ART mgh122.dat 212 20 12 0 40 10045 0 PAP mgh122.dat 212 20 12 0 -1016 13731 0 CVP mgh122.dat 212 1000 12 0 466 -18130 0 Resp. Imp. mgh122.dat 212 1000 12 0 -944 -9017 0 CO2 #: 61 : F : Cardiac arrest; Post-mitral valve replacement # GENERAL COMMENTS: # Recording begins with ECG recording only # Cardiac massage is initiated # ECG electrodes fall off # Arterial tracing is turned on # Electrodes are changed # ECG and arterial traces are recorded during massage @ 16 min # Massage is intermittently stopped, then resumed throughout tracing # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Sinus tachycardia with intraventricular conduction delay # RHYTHM DISTURBANCES: # Idioventricular rhythm # ECG INTERPRETATION: # Nonspecific T wave abnormalities # RESPIRATORY DATA: # MODE OF VENTILATION: # Controlled and ambu ventilation