ST ANNOTATIONS IN THE RECORD s20131 (Duration: 20:55:10.000) Starting time, recording date: 13:43:00 17/05/1995 Lead 0: ML2 Lead 1: MV2 A. Criteria of 30 seconds and 75 microVolts (s20131.sta) Lead 0: Ischemic episodes: 31 Duration: 4:35:04 21.91% Rate-related episodes: 0 Duration: 0:00 0.00% Axis shifts: 2 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Lead 1: Ischemic episodes: 0 Duration: 0:00 0.00% Rate-related episodes: 4 Duration: 28:14 2.25% Axis shifts: 0 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Total: Ischemic episodes: 31 Duration: 4:35:04 10.96% Rate-related episodes: 4 Duration: 28:14 1.12% Axis shifts: 2 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Combined: Ischemic episodes: 31 Duration: 4:35:04 21.91% Rate-related episodes: 8 Duration: 20:02 1.60% Unreadable intervals: 0 Duration: 0:00 0.00% Combined [ischemic or rate-related]: ST segment episodes: 26 Duration: 4:55:06 23.51% Unreadable intervals: 0 Duration: 0:00 0.00% B. Criteria of 30 seconds and 100 microVolts (s20131.stb) Lead 0: Ischemic episodes: 19 Duration: 4:10:08 19.93% Rate-related episodes: 0 Duration: 0:00 0.00% Axis shifts: 2 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Lead 1: Ischemic episodes: 0 Duration: 0:00 0.00% Rate-related episodes: 1 Duration: 9:42 0.77% Axis shifts: 0 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Total: Ischemic episodes: 19 Duration: 4:10:08 9.96% Rate-related episodes: 1 Duration: 9:42 0.39% Axis shifts: 2 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Combined: Ischemic episodes: 19 Duration: 4:10:08 19.93% Rate-related episodes: 2 Duration: 8:28 0.67% Unreadable intervals: 0 Duration: 0:00 0.00% Combined [ischemic or rate-related]: ST segment episodes: 18 Duration: 4:18:36 20.60% Unreadable intervals: 0 Duration: 0:00 0.00% C. Criteria of 60 seconds and 100 microVolts (s20131.stc) Lead 0: Ischemic episodes: 16 Duration: 4:00:48 19.18% Rate-related episodes: 0 Duration: 0:00 0.00% Axis shifts: 2 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Lead 1: Ischemic episodes: 0 Duration: 0:00 0.00% Rate-related episodes: 1 Duration: 9:42 0.77% Axis shifts: 0 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Total: Ischemic episodes: 16 Duration: 4:00:48 9.59% Rate-related episodes: 1 Duration: 9:42 0.39% Axis shifts: 2 Conduction-change shifts: 0 Noisy events: 0 Unreadable intervals: 0 Duration: 0:00 0.00% Combined: Ischemic episodes: 16 Duration: 4:00:48 19.18% Rate-related episodes: 1 Duration: 9:34 0.76% Unreadable intervals: 0 Duration: 0:00 0.00% Combined [ischemic or rate-related]: ST segment episodes: 16 Duration: 4:10:22 19.95% Unreadable intervals: 0 Duration: 0:00 0.00% QRS ATRUTH ANNOTATIONS (s20131.atr) Total number of beats 106300 Normal beats 105765 Aberrated atrial premature beats 1 Premature ventricular contractions 495 Fusions of ventricular and normal beat 6 Supraventricular premature or ectopic beats 33