PhysioBank
|
Advanced Search |
Tour |
Mirrors How to Cite | Contributing | FAQ |
||
| |||
An initial set of beat labels was produced by a slope-sensitive QRS detector, which marked each detected event as a normal beat. Each two-hour, two-channel ECG record was printed out in full disclosure format, each page two minutes in duration, with the addition of QRS detection marks, trend plots of ST segment displacement and T-wave amplitude (measured for each beat), and boxes for checking annotation operations. For each record, two cardiologists (neither of whom was a member of the research group which had submitted the record) were given copies of the full-disclosure printout, trend plots of mean heart rate and ST-T parameters at 10-second intervals, and record-specific transparent plastic rulers for measuring time intervals and ECG signal displacements. A heart rate scale and a two-channel reference QRST complex (taken from the first 30 seconds of each record) were printed on each ruler.
Working independently, the cardiologist-annotators visually checked the computer-generated beat labels on the full-disclosure printouts and manually corrected them, and inserted annotations indicating changes in ST and T morphology, rhythm, and signal quality. Annotations from the two cardiologists were compared and the differences were resolved by a cardiologist of the coordinating group. This method assumes that the third cardiologist is able to make a more reliable judgement since he knows both sets of annotations.
The cardiologists participating in the project jointly defined and followed a set of rules for locating ST episodes and T episodes (i.e., intervals during which the ECG exhibits significant ST segment or T-wave changes). To identify and annotate an ST episode, these criteria were applied:
These rules were applied to each of the two signals independently; for this reason, each ST and T change annotation indicates the signal to which it applies.
Each ST and T change annotation contains a text field which describes its significance. The text field contains characters which identify the episode type ('ST' or 'T'), the signal number ('0' or '1'), and the direction of the deviation ('+' or '-'; extreme T deviations are signified by '++' and '--'). The text field of an annotation which marks the beginning of an episode contains a '(' prefix. For an annotation which marks the end of an episode, there is a prefixed 'A' and an appended 3- or 4-digit decimal number which expresses the magnitude of the peak deviation in microvolts. An annotation which marks the end of an episode has a ')' appended to the end of its text field. For example, an episode of ST depression in signal 0 with a peak (absolute) deviation of 200 microvolts would be marked by three annotations, with text fields of '(ST0-', 'AST0-200', and 'ST0-)'.
In six records (e0161, e0509, e0601, e0611, e0613, and e0615), axis shifts resulting from positional change give the appearance of real ST or T changes. These axis shifts are annotated using comment annotations. The text fields of these annotations are constructed in the same way as for ST and T change annotations, except that lower-case characters are used in order to make it easier to distinguish these axis shift episodes from real ST or T change episodes. For example, an axis shift in signal 1 which gives the appearance of a peak T deviation of 350 microvolts would be marked by three annotations, with text fields of '(t1+', 'at1+350', and 't1+)'.
The following types of annotations appear in the European ST-T Database reference (.atr) annotation files. The Code column shows the symbols defined in ecgcodes.h, and the Mnemonic column indicates how these annotations are displayed by WFDB applications such as WAVE, WVIEW, and pschart.
| Code | Mnemonic | Meaning | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NORMAL | [bullet] | Normal beat | ||||||||||||||||||||
| ABERR | a | Aberrated atrial premature beat | ||||||||||||||||||||
| NPC | J | Nodal (junctional) premature beat | ||||||||||||||||||||
| SVPB | S | Supraventricular premature or ectopic beat (atrial or nodal) | ||||||||||||||||||||
| PVC | V | Premature ventricular contraction | ||||||||||||||||||||
| FUSION | F | Fusion of ventricular and normal beat | ||||||||||||||||||||
| UNKNOWN | Q | Unclassifiable beat | ||||||||||||||||||||
| ARFCT | | | Isolated QRS-like artifact | ||||||||||||||||||||
| RHYTHM | Rhythm change, specified by text field:
| |||||||||||||||||||||
| STCH | ST change, specified by text field:
| |||||||||||||||||||||
| TCH | T change, specified by text field:
| |||||||||||||||||||||
| NOTE | Comment annotation, specified by text field:
| |||||||||||||||||||||
| NOISE | Signal quality change: the first character ('c', 'n', or 'u')
indicates the quality of signal 0 (clean, noisy, or unreadable),
and the second character indicates the quality of signal 1.
The subtyp field of the annotation encodes these
characters:
|
| Send feedback about this page to PhysioNet |
|
Your comments and suggestions are welcome. We encourage you to use our feedback form to comment on this page. If you would like to receive a reply, please send your comments by email to webmaster@physionet.org, or post them to: MIT Room E25-505A 77 Massachusetts Avenue Cambridge, MA 02139 USA |
![]() |
Updated Friday, 09-Feb-2001 01:02:04 EST